51 22 280 Removing and installing/replacing door stop on left or right rear door
Necessary preliminary tasks:
- Close door windows
- Remove the SOUND INSULATION in front section
NOTE:
Secure rear door against falling closed.
After disengaging door stop, use suitable means of preventing door from opening past its maximum permissible opening angle (risk of damaging paintwork or bodywork).
After disengaging door stop, use suitable means of preventing door from opening past its maximum permissible opening angle (risk of damaging paintwork or bodywork).
Pull out rubber cover (1).
Release screw (3).
Tightening torque, refer to: 51 22 5AZ .
Release screw (2).
Tightening torque, refer to: 51 22 3AZ .
Slide out door stop.
Installation note:
Seal (1) must not be damaged.
Remove door stop (1) via aperture (2).
Installation note:
Following parts of door retainer (3) must not be damaged:
- Hinge
- Thread