67 62 020 Removing and installing/replacing flat motor for rear left or right power window regulator
Necessary preliminary tasks:
- Remove REAR POWER WINDOW REGULATOR
Release screw connections (1).
Remove flat motor (2) from power window regulator.
Cable must not come loose from power window.
Installation note:
Simultaneously tighten both screw connections (1).
The shaft of the flat motor (2) must be pulled into the holder of the power window regulator under slight tension.
Tightening torque 51 35 1AZ .
Flat motor (2) must engage exactly at the marked points of the power window regulator (1).
IMPORTANT:
Ensure that the flat motor (2) is assembled without tension.
After installation:
An initialization must be carried out in order to activate anti-trap mechanism.
Read and comply with NOTES on initialization of power window regulator.