12 14 650 Replacing suction pressure sensor on intake plenum (N20)
WARNING: This page is about a different variant/trim than selected.
Necessary preliminary tasks:
- Read out the fault memory of the DME control unit.
- Switch off ignition.
- Partially undo the acoustic cover.
Unlock connector (1) and remove.
Unfasten screws (2).
Tightening torque 13 62 5AZ .
Pull out the vacuum pressure sensor (3) from the intake plenum.
Installation note:
Check sealing ring for damage. Replace damaged sealing ring.
When installing, coat sealing ring with suitable lubricant.
NOTE:
Reassemble the vehicle.
Check stored fault message.
Delete fault memory.
Check stored fault message.
Delete fault memory.