18 12 050 Replacing center silencer (N74)
Only perform these tasks after exhaust system has cooled down.
Support center silencer with special tool 31 2 220 and a suitable universal lifter.
Release screws (1).
Tightening torque: see 2AZ in 18 20 EXHAUST SYSTEM SUSPENSION
Only when auxiliary heater is fitted: release screw (2) on metering pump.
Tightening torque: see 3AZ in 18 20 EXHAUST SYSTEM SUSPENSION
Release screws (3) on underbody panelling.
Remove reinforcement plate (4).
Carry over separation point to faulty center silencer (2) and mark out.
Secure center silencer against falling off.
Cut through exhaust pipes at marked point with a suitable tool.
Picture shows the left side, the procedure for the right side is identical.
Detach the center silencer from the rubber mount (1).
Lower and remove center silencer with assistance of a second person.
Check rubber mount for damage. Replaced damaged rubber mounts.
Installation note:
Adjust center silencer to fit and connect with clamps.
Centre clamps and tighten down.
Tightening torque: see 2AZ in 18 31 EXHAUST SYSTEM
The procedure is identical on both sides.