LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2016 >> Z4 sDrive35is >> Repair and Diagnosis >> External Pages >> Different car >> Section 1425 (Cooling System - Repair (N55, 2013-)) >> Safety And General Information >> 17 00 039 Venting and filling cooling system with vacuum filling unit

17 00 039 Venting and filling cooling system with vacuum filling unit

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2015 BMW 740i, 2015 BMW 740Li xDrive, 2015 BMW 740Li, 2014 BMW 740i, and 2014 BMW 740Li xDrive. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

IMPORTANT: Lifetime coolant filling:
Never reuse used coolant!
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be drained and refilled.
In the case of other removal work involving the draining of part quantities of coolant, replace these quantities which have been drained with new coolant.
IMPORTANT: You must protect the alternator against contamination by coolant when carrying out repair work on the cooling circuit.
Cover alternator with suitable materials.
Failure to comply with this procedure may result in an alternator malfunction.

(order number 81 39 2 152 473)

IMPORTANT: Risk of slipping due to coolant on the floor.
Danger of injury!

Catch and dispose of emerging coolant in drip tray (1) and if necessary special tool 00 2 030 (universal hydraulic lifting equipment).

Recycling: 

Observe country-specific waste disposal regulations.

Fig 1: Identifying Drip Tray And Special Tool (00 2 030)
G05476170Courtesy of BMW OF NORTH AMERICA, INC.

Graphic shows the N63 engine (procedure for other engines identical).

IMPORTANT: Check all the coolant hoses before filling the cooling system with the vacuum filling unit.
If necessary, replace damaged and porous coolant hoses.

Vacuum filling unit consists of: 

Fig 2: Identifying Vacuum Filling Unit Components
G06889241Courtesy of BMW OF NORTH AMERICA, INC.

Preconditions 

Application 

Connect filling unit (1) with adapter (2) 17 0 113 to coolant expansion tank.

Shutoff valves (A) and (B) must be closed.

Fig 3: Identifying Coolant Filling Unit, Adapter And Shut-Off Valves
G06889242Courtesy of BMW OF NORTH AMERICA, INC.

Connect venturi nozzle (1) to filling unit (2).

Fig 4: Connecting Venturi Nozzle To Filling Unit
G06889243Courtesy of BMW OF NORTH AMERICA, INC.

Connect compressed air (1) and open shutoff valve (B).

The venturi nozzle produces a flow noise.

Fig 5: Connecting Compressed Air And Shutoff Valve
G06889244Courtesy of BMW OF NORTH AMERICA, INC.

Then open shutoff valve (A) until the filling hose (1) is free of bubbles. Close shutoff valve (A) again. The filling hose (1) is vented in this way.

Fig 6: Identifying Filling Hose And Shut-Off Valve
G06889245Courtesy of BMW OF NORTH AMERICA, INC.

Shutoff valve (B) remains open. Generate vacuum in cooling cycle for approx. 1 minute. The end vacuum is reached at a vacuum of -0.7 to -0.95 bar. Green scale on the vacuum meter.

NOTE: The coolant hoses contract during vacuum build-up.
Fig 7: Connecting Compressed Air And Shutoff Valve
G06889244Courtesy of BMW OF NORTH AMERICA, INC.

Then close shutoff valve (B) again.

Both shutoff valves (A) and (B) must be closed. Then seal Venturi nozzle (1).

Fig 8: Identifying Venturi Nozzle And Shutoff Valves
G06889247Courtesy of BMW OF NORTH AMERICA, INC.

The cooling system must hold the vacuum for 30 seconds. If the needle in the vacuum meter falls, this indicates a leak in the cooling system.

If the vacuum remains constant, proceed with filling.

In the event of leaks, check COOLING SYSTEM FOR LEAKS .

Fig 9: Checking Cooling System For Leaks
G06889248Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: There must be sufficiently premixed coolant in the filling unit container, 1 - 2 liters more than the vehicle filling CAPACITY .
Position the filling unit container at the same height as the coolant expansion tank.

Shut-off valve (B) remains closed during the filling process.

To fill the cooling system, open shutoff valve (A) to filling unit container.

Coolant is now added.

The filling procedure is finished when the needle in the vacuum meter is at 0 bar or no longer falls.

If necessary, reduce remaining vacuum. Open shutoff valve (B) to do so.

Fig 10: Identifying Cooling System Shut-Off Valves
G06889249Courtesy of BMW OF NORTH AMERICA, INC.

Remove filling unit with adapter from expansion tank.

Adjust coolant level to maximum.

Fig 11: Checking Coolant Level
G06889232Courtesy of BMW OF NORTH AMERICA, INC.

Close coolant expansion tank.

Installation note: 

Close the sealing cap (1) until the arrows line up.

Fig 12: Identifying Coolant Expansion Tank Sealing Cap
G06889230Courtesy of BMW OF NORTH AMERICA, INC.

After the cooling system has been filled with the vacuum filling unit, another BLEEDING PROCEDURE  must be performed.

Check function of cooling system.

Visual inspection of cooling system for tightness.