Action in service
1st step: Check deactivation path for clutch 2:
Test routine 'Test_CutOff_K2_02 '
1st step: Case 1: Pressure level remains constant in clutch 2
2nd step: Shift valve defective
=> Replace mechatronic module
1st step: Case 2: No pressure in clutch 2 2nd step: => PV2, Check 0 position:
Test routine 'Test_PV2-0_02 '
2nd step: Case 1: Pressure < 1.8 bar in clutch 2 3rd step: => Delete diagnostic fault code
2nd step: Case 2: Pressure >= 1.8 bar in clutch 2 3rd step: Defective control valve
=> Replace mechatronic module