LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2016 >> X5 M >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning -- Repair X5 M (F85) >> 64 53 Air Conditioning Condenser And Dryer With Lines >> Replacing double pipe (X5 M)

Replacing double pipe (X5 M)

Special tools required: 

WARNING: Danger of injury! 
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant oil.
Read and comply with safety information:
IMPORTANT: Risk of damage! 
Restart engine only when air conditioning has been correctly filled.
Follow NOTES  for opening and replacing parts in refrigerant circuit.
If air conditioning is opened for more than 24 hours:  Replace DESICCANT INSERT FOR AIR CONDITIONING .

Necessary preliminary tasks: 

Release screw (1).

Installation note: 

Check that rubber seal is correctly seated.

Tightening torque 64 53 1AZ .

G04792676Courtesy of BMW OF NORTH AMERICA, INC.

Release screws (1) and remove refrigerant lines.

Tightening torque 64 53 5AZ .

Remove refrigerant line from double pipe holder (2).

Installation note: 

Replace sealing rings.

Use special tool 00 9 030 to install sealing rings without damaging them.

G04792677Courtesy of BMW OF NORTH AMERICA, INC.

After installation: