17 00 009 Checking Water Tightness Of Cooling System (S63 B44 T 0)
Special tools required:
Only perform this repair work after engine has cooled down.
Protective measures/rules of conduct:
- Wear safety goggles.
- Wear protective gloves.
- Observe national/country-specific regulations.
Danger of injury!
Catch and dispose of drained coolant in drip tray (1) and if necessary special tool 00 2 030 (universal hydraulic lifting equipment).
Recycling:
Observe country-specific waste disposal regulations.
Checking pressure drop in cooling system:
Open the sealing cap on the coolant expansion tank. Mount special tool (1) 17 0 101 and (2) 17 0 113 from the set of special tools 17 0 100 .
Build up GAUGE PRESSURE and wait approx. 2 minutes.
Cooling system is impervious to watertightness if pressure drop is max. 0.1 bar.
Checking pressure relief valve in sealing cap:
Replace the sealing cap only after you have checked three times and there is an incorrect opening pressure .
Checking pressure relief valve in sealing cap:
Screw sealing cap (1) onto special tool 17 0 114 from the special tool set 17 0 100 .
Use special tool (hand pump) 17 0 101 from the special tool set 17 0 100 to build up pressure; observe pressure gauge to ascertain when opening pressure is achieved.
Compare OPENING PRESSURE of pressure relief valve.