Condition for fault identification
Voltage condition:
System voltage > 10 V
Temperature condition:
None
Time condition:
None
Other conditions:
E7X: Air mass flow > 272 mg/stroke; engine speed > 2820 RPM
F01: Drive torque > 46 Nm; engine speed > 1450 RPM