Install the Headunit High (HU-H)
- Connect and lock the connector (3) to the head unit (4).
- Correctly position the cable clip (2) and engage it with the detent (1).
NOTE:
RISK OF DAMAGE
Damage to the instrument cluster (KOMBI) or the head unit
A ground offset can occur when releasing and connecting the cables. This can generate currents that render the instrument cluster (KOMBI) or the head unit unusable.
Damage to the instrument cluster (KOMBI) or the head unit
A ground offset can occur when releasing and connecting the cables. This can generate currents that render the instrument cluster (KOMBI) or the head unit unusable.
- When releasing: First release the APIX data cable (blue).
- When connecting: Connect the APIX data cable (blue) last.
- Connect and lock all the connectors in the marked area with head unit (1) in the correct assembly sequence.
All cables must be routed correctly.
- Push the head unit (2) into the dashboard and tighten the screws (1).
TIGHTENING TORQUE SPECIFICATIONS
| Head unit to dashboard | ||
| screw | Tightening torque | 1.8 Nm |
Follow-up work