11 51 025 Removing and installing/replacing auxiliary water pump for electrical machine electronics (N55 Hybrid)
WARNING:
Compliance with the following points is mandatory before beginning work:
- Observe SAFETY INFORMATION for handling electric vehicles.
WARNING:
Risk of scalding!
Only perform this work after engine has cooled down.
Only perform this work after engine has cooled down.
IMPORTANT:
If a coolant pump that has already been operated is reused, it must be filled with coolant after removal.
Mixture ratio, water: coolant = 1: 1
Protect plug connections against coolant and contamination.
Mixture ratio, water: coolant = 1: 1
Protect plug connections against coolant and contamination.
Recycling:
Catch and dispose of drained coolant in a suitable container.
Observe country-specific waste disposal regulations.
Necessary preliminary work:
- Drain COOLANT for electrical machine electronics.
Release screw (2).
Tightening torque 17 10 5AZ .
Unlock locks (3) in direction of arrow. Pull off expansion tank upwards from carrier support, lay expansion tank to one side.
Disconnect plug connection (1).
Unlock and detach coolant hose (2).
Release coolant hose (3).
Installation note:
Note installation hose clamps.
Tightening torque 11 53 9AZ .
Release nuts (4) and remove auxiliary water pump.
BLEEDING INSTRUCTIONS must be observed without fail.