LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2016 >> 320i xDrive >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Engine Electrical System - Repair - F30 >> PREHEATER Plugs >> 12 23 505 Replacing all glow elements (N47 D16/20 K/U/O/T 1)

12 23 505 Replacing all glow elements (N47 D16/20 K/U/O/T 1)

Special tools required: 

NOTE: When one or more glow elements are replaced, the preheating control service function must be started with the BMW diagnosis system before replacement and the "Security data record in the preheating control must be activated".
NOTE: If malfunctions have occurred at the glow elements, it is essential to check the safety fuse.
Switch off ignition.
NOTE: It is recommended to warm the engine up to operating temperature for easy removal of glow elements. In addition, spray glow element with DISASSEMBLY AGENT 5.1 and let it take effect for approx. 2 minutes. Removing glow elements from a cold engine may cause damage to the thread in the cylinder head.
IMPORTANT: Risk of burning! The use of gloves is mandatory!

Necessary preliminary tasks: 

Release screw (1).

Unlock connector from cable channel and pull off. Slide cable channel (2) to one side.

Fig 1: Identifying Screw And Cable Channel
G09945558Courtesy of BMW OF NORTH AMERICA, INC.

Version 1: 

Compress connector fastener (1) with special tool 12 2 300 and pull connectors from glow elements.

NOTE: For purposes of clarity, the intake plenum is shown removed.
Fig 2: Compressing Connector Fastener
G09914172Courtesy of BMW OF NORTH AMERICA, INC.

Version 2: 

Pull connector (1) from glow element with special tool 11 1 480 .

Fig 3: Pulling Connector From Glow Element With Special Tool (11 1 480)
G09914173Courtesy of BMW OF NORTH AMERICA, INC.

Unscrew glow elements with special tool 11 6 050 .

Tightening torque: 12 23 1AZ .

NOTE: For purposes of clarity, the intake plenum is shown removed.
Fig 4: Releasing Glow Elements Screws With Special Tool (11 6 050)
G09914174Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: If one or more glow elements are renewed, the preheating control service function must be performed using the diagnosis system after they are replaced.

Read out fault code memory in DDE control unit. Check stored fault message. Rectify fault. Delete fault memory.