64 51 001 Cleaning evaporator: Recycling

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2016 BMW 760Li, 2015 BMW 760Li, 2014 BMW 760Li, 2013 BMW 760Li, and 2012 BMW 760Li. However, it is still accessible from the selected car via links, so may be relevant.

Carry out the cleaning operation in a suitable washing bay as the emerging cleaning agent escapes through the drain openings in the transmission tunnel.

After completing cleaning, allow car to drip-dry for approx. 5 minutes.

Necessary preliminary tasks: 

NOTE: Cleaning procedure must be performed in two steps with special tool 2 222 502 .
Fig 1: Inserting Special Tool (2 222 502) In Rear Opening Of Microfilter Housing
G08510077Courtesy of BMW OF NORTH AMERICA, INC.

Step 1:

Insert special tool 2 222 502 in the rear opening of the microfilter housing (1) at position (2) as shown.

Fig 2: Inserting Special Tool (2 222 502) In Rear Opening Of Microfilter Housing At Position
G08510078Courtesy of BMW OF NORTH AMERICA, INC.

Move special tool 2 222 502 from top downwards (A) up to stop.

At the same time, press special tool 2 222 502 at position (1) in the direction of the arrow against the microfilter housing.

Spray approximately half of the cleaning agent. Then pull the special tool 2 222 502 out of the microfilter housing.

Fig 3: Pulling Special Tool (2 222 502) Out Of Microfilter Housing
G08510079Courtesy of BMW OF NORTH AMERICA, INC.

Step 2:

Insert special tool 2 222 502 in the rear opening of the microfilter housing (2) at position (1) as shown.

Fig 4: Inserting Special Tool (2 222 502) In Rear Opening Of Microfilter Housing At Position
G08510080Courtesy of BMW OF NORTH AMERICA, INC.

Move special tool 2 222 502 from top downwards (A) up to stop.

At the same time, press special tool 2 222 502 at position (1) in the direction of the arrow against the microfilter housing.

Spray the remaining half of the cleaning agent. Then pull the special tool 2 222 502 out of the microfilter housing.

NOTE: Set heating - A/C system to footwell ventilation and fresh-air mode. Open side windows/doors.
Start the vehicle and let the heating and air conditioning system run for at least 5 minutes at maximum blower output.

In order to eliminate the last remnants of cleaning agent, repeat this process shortly before handover to the customer.