11 78 610 Replacing oxygen monitoring sensors (N20)
Special tools required:
- 11 7 030
WARNING:
Risk of burning.
Work should only be carried out on an exhaust system that has cooled down.
Necessary preliminary work:
- Remove CATALYTIC CONVERTER .
Installation note:
The threads of new oxygen monitoring sensors are already coated with NEVER-SEEZ COMPOUND .
If a lambda monitoring sensor is to be reused, apply a thin and even coating of Never-Seez Compound to the thread only.
Sensor ceramics must not be cleaned and not be coated with lubricant.
Disconnect plug connection on lambda monitoring sensor (1).
Installation note:
Cable color of oxygen control sensor = black.
Cable color of oxygen monitoring sensor = grey.
Release oxygen monitoring sensor with special tool 11 7 030.
Tightening torque 11 78 2AZ .
Reassemble the vehicle.
Check function of DME.