66 54 001 Axially adjusting night vision camera
NOTE:
Mechanical setting - as described in the following - is only possible axially
.
Vertical alignment can only be carried out with the BMW diagnosis system:
Vertical alignment can only be carried out with the BMW diagnosis system:
- Service functions
-> Driver assistance systems
-> Night vision electronics
-> Calibration night vision electronics camera
NOTE:
Installation location: Adjusting screw, Night Vision Camera F01, 02, 03:
Fold lid (1) in engine compartment lid gasket fixture mounting upwards as pictured.
NOTE:
(2) = Installation location, adjusting screw, night vision camera
NOTE:
Installation location: Adjusting screw, Night Vision Camera F07, F10, 11, 18, F12, 13:
Fold up engine compartment lid seal (1) as shown.
NOTE:
(2) = Installation location, adjusting screw, night vision camera
NOTE:
Front of vehicle must be parallel at distance (A) to headlight aiming device (1).
(A) = 2 m
Align a suitable straight object (2), e.g. a spirit level, horizontally on headlight aiming device.
Slowly carry out axial adjustment of night vision camera at adjusting screw (3).
NOTE:
Image shows the CID picture in the vehicle.
If necessary, align the image of the night vision camera with aid of a second person.
Yellow help line (1) is displayed using diagnosis job.
Upper edge (2) must be aligned using adjusting screw parallel to yellow help line (1) in the CID.
If necessary, align the image of the night vision camera with aid of a second person.
Yellow help line (1) is displayed using diagnosis job.
Upper edge (2) must be aligned using adjusting screw parallel to yellow help line (1) in the CID.