Fault description
Diagnosis monitors the electrical connection between DME and sensor 1 in the accelerator pedal.
The fault is detected when the voltage of pedal position sensor 1 is < 0.15 V.
Possible fault cause:
- Wiring harness between DME and accelerator pedal module defective (M_FWG1, U_FWG1, A_FWG1)
- Accelerator pedal module defective