Home >> BMW >> 2015 >> 760Li >> Repair and Diagnosis >> Engine Performance >> System >> Self Diagnosis (N74) - 760LI - DTC P11AA - P110F (BMW DTC 100401 - 10B104) >> DTC P111E: BMW DTC 108201; DME -- Intake Air Temperature Sensor 1 Maximum Temperature Implausible (Bank 1) >> Condition for fault identification

Condition for fault identification

Voltage condition:

None

Temperature condition:

The ambient temperature at engine start must be higher than -7.5°C

$(C TAM MIN TIA PLAUS DIAG) and lower than 35.3°C

$(C_TAM_MAX_TIA_PLAUS_DIAG).

Time condition:

None

Other conditions:

speed >40 km/h $(C VS MIN TIA PLAUS DIAG) for >120 s $(C_T_VS_MIN_TIA_PLAUS_DIAG)