Condition for fault identification
Temperature related-precondition:
Intake air temperature greater than the lower limit value and lower than the upper limit value:
- lower limit value: -30 °C
- upper limit value: 120 deg C
Coolant temperature higher than the following limit value: -30 °C
Time related-precondition:
- Time after start more than the following limit value: 10 s
Other preconditions:
- Engine running.
Ambient pressure higher than the following limit value: 745 mbar
Engine speed is greater than the lower limit value and less than the upper limit value:
- lower limit value: 500 RPM
- upper limit value: 7100 RPM
Dynamics of the engine speed (change in speed per second) less than the following limit value: between 133 RPM and 200 RPM (depending on the version).
Dynamics of the load (change of the load per second) is less than the following limit value: 7%
Approach constant operating points in the charged area.
Control unit voltage: 9 V to 16 V.
Terminal 15 on