Condition for fault identification
Other voltage related preconditions:
- Supply voltage between 9 V and 16 V.
Temperature related-precondition:
- Coolant temperature upper limit value: 60 deg C
Time related-precondition:
- Waiting period after engine start greater than limit value: 280 s
- 10 min constant-speed driving with speed between 85 km/h and 130 km/h
Other preconditions:
- Engine speed between the following limits:
Automatic transmission
lower limit: CILCN_nOpRngLoLoAt_C
upper limit: CILCN_nOpRngLoHiAt_C
Gear higher than/equal to: CILCN_numGearMinAt_C
Manual transmission
lower limit: CILCN_nOpRngLoLoMt_C
upper limit: CILCN_nOpRngLoHiMt_C
Gear higher than/equal to: CILCN_numGearMinMt_C
Terminal status:
- Terminal 15 on.