64 53 517 Replacing desiccant insert for air conditioning system
Special tools required:
Refrigerant circuit is under high pressure!
Observe SAFETY INFORMATION for handling refrigerant and refrigerant oil.
Avoid contact with refrigerant and refrigerant oil.
Restart engine only when A/C system has been correctly filled.
Follow notes for OPENING AND REPLACING PARTS in refrigerant circuit.
If air conditioning system is opened for more than 24 hours: replace desiccant insert for air conditioning system
Follow INSTRUCTIONS ON REPLACING DESICCANT INSERT .
Necessary preliminary tasks:
The condenser does not need to be removed for the following operations!
Remove protective cap (1) from capacitor (2).
Press sealing cap (1) inwards and remove circlip (2).
With assistance of a screwed-in screw (1), remove sealing cap (2) from capacitor (3).
Installation note:
Replace sealing rings (1).
Use special tool 00 9 030 to fit sealing rings (1) without damaging them.
Removal is made more difficult if rib (2) is damaged!
Carefully pull out desiccant insert (1) with a pair of wide pliers on rib (2).
After installation: