LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 92 (Intake Plenum, Turbocharger, Vacuum Pump, EGR Valve, Oxygen Sensors - Repair) >> Turbocharger >> 11 65 180 Removing and installing/renewing heat shield at top (N63O1)

11 65 180 Removing and installing/renewing heat shield at top (N63O1)

WARNING: This page is about a different variant/trim than selected.
IMPORTANT: Do not carry out test drives without heat shield (risk of fire!)  .

Necessary preliminary tasks: 

Release retaining clip (1).

Detach wire ring (2) and set down behind oxygen sensor.

Fig 1: Identifying Retaining Clip And Wire Ring
G10058017Courtesy of BMW OF NORTH AMERICA, INC.

Release bolts (1) through 180°.

Tightening torque 11 65 3AZ .

Fig 2: Identifying Heat Shield Bolts
G10058018Courtesy of BMW OF NORTH AMERICA, INC.

Release bolts (1) through 180°.

Tightening torque 11 65 3AZ .

Fig 3: Identifying Heat Shield Bolts
G10058019Courtesy of BMW OF NORTH AMERICA, INC.

Lift out heat shield.

Installation note: 

Clip in heat shield (1) into retaining clip, see arrow.

Fig 4: Identifying Heat Shield Retaining Clip
G10058020Courtesy of BMW OF NORTH AMERICA, INC.

Assemble engine.