LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (Heating And Air Conditioning - Repair - F13) >> Heater With Operation >> 64 11 865 (N52T, N55) Replacing actuator drive of recirculated air flap

64 11 865 (N52T, N55) Replacing actuator drive of recirculated air flap

WARNING: This page is about a different variant/trim than selected.

Necessary preliminary tasks: 

Unlock and disconnect all plug connections.

Unlatch connector housing (1 and 2) from guide of auxiliary E-box (3).

Fig 1: Locating Auxiliary E-Box Connector Housing
G09875482Courtesy of BMW OF NORTH AMERICA, INC.

Release screw (1).

Carefully unlock retaining hook (2) while lifting E -box3) and simultaneously pulling forward

Installation note: 

Ensure guide lug (2) sit correctly in the respective recesses of the fan housing.

Fig 2: Identifying Guide Lug, Retaining Hook, Screw
G09929250Courtesy of BMW OF NORTH AMERICA, INC.

Unlock plug connection (1) on AUC sensor (2) and disconnect.

Fig 3: Identifying AUC Sensor Plug Connection
G06886157Courtesy of BMW OF NORTH AMERICA, INC.

Release screws (1) on blower housing cover (2).

Lift out blower housing cover.

Fig 4: Identifying Blower Housing Cover Screws
G06886158Courtesy of BMW OF NORTH AMERICA, INC.

Release screws (1).

Unclip relay lever (2) with a suitable tool.

Remove actuator drive (3).

Unlock plug connection (4) and disconnect.

Fig 5: Identifying Actuator Drive Plug Connection, Relay Lever, Screws
G06886221Courtesy of BMW OF NORTH AMERICA, INC.

Replacement: 

Servomotors must be re-addressed in the event of replacement!

Addressing can only be carried out with the BMW diagnosis system.

Service functions: