64 11 831 Replacing actuator drive for outer right ventilation flap
WARNING: This page is about a different variant/trim than selected.
Necessary preliminary tasks:
- Remove INSTRUMENT PANEL TRIM
Position of actuator drive:
OVERVIEW OF ACTUATOR DRIVES ON HEATING AND AIR-CONDITIONING UNIT
Release screws (1).
Remove actuator drive (2) and unlock and disconnect plug connection (3).
Replacement:
Servomotors must be readdressed in the event of replacement!
Addressing can only be carried out with the BMW diagnosis system.
Service functions:
- Body
- Heating and air conditioning function
- Flap motors
- Readdress flap motors