16 19 010 Drawing off SCR active reservoir content
WARNING: This page does not describe the selected car, but rather 50 other vehicles, including the 2016 BMW M5, 2016 BMW ActiveHybrid 5, 2016 BMW 550i xDrive, 2016 BMW 550i, and 2016 BMW 535i xDrive. However, it is still accessible from the selected car via links, so may be relevant.
Special tools required:
- 2 302 782
- 2 302 919
- 2 355 173
IMPORTANT:
Ensure adequate ventilation in the workbay!
Avoid skin contact (wear gloves)!
Avoid eye contact (safety goggles)!
Urea/water mixture can escape when components carrying urea/water mixture are released. Have a collecting vessel ready.
Observe country-specific waste disposal regulations.
Avoid skin contact (wear gloves)!
Avoid eye contact (safety goggles)!
Urea/water mixture can escape when components carrying urea/water mixture are released. Have a collecting vessel ready.
Observe country-specific waste disposal regulations.
IMPORTANT:
Maintain conditions of absolute cleanliness.
Connections and covers of lines carrying urea/water mixture must be cleaned thoroughly with water after each removal or before each installation!
Thoroughly clean the working area with water after repair work.
Use fluff-free cloths for cleaning.
Close connections and lines!
Thoroughly clean special tool with water after each use.
Connections and covers of lines carrying urea/water mixture must be cleaned thoroughly with water after each removal or before each installation!
Thoroughly clean the working area with water after repair work.
Use fluff-free cloths for cleaning.
Close connections and lines!
Thoroughly clean special tool with water after each use.
IMPORTANT:
Use extractor unit 2 302 782 (for 230V) or 2 302 919 (for 120V).
Attach adaptor hose 2 355 173 to the intake side of the extractor unit.
Before start-up of extractor unit urea/water mixture:
Comply with equipment manufacturer's operating instructions and safety regulations.
Note extraction direction (see arrow)!
Attach adaptor hose 2 355 173 to the intake side of the extractor unit.
Before start-up of extractor unit urea/water mixture:
Comply with equipment manufacturer's operating instructions and safety regulations.
Note extraction direction (see arrow)!
Feed adaptor hose 2 355 173 of the extractor unit into the filler pipe (1).
The extraction hose may need to be twisted when inserting it.
IMPORTANT:
Insertion length of extraction hose 100 cm!
Draw off urea/water mixture.
NOTE:
Do not reuse drawn-off urea/water mixture.