Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 807 (Heating And Air Conditioning - Repair) >> Condenser And Dryer With Lines >> 64 53 551 Removing and installing/replacing capacitor for the heating and air conditioning system (N63)

64 53 551 Removing and installing/replacing capacitor for the heating and air conditioning system (N63)

WARNING: This page does not describe the selected car, but rather 50 other vehicles, including the 2016 BMW M5, 2016 BMW ActiveHybrid 5, 2016 BMW 550i xDrive, 2016 BMW 550i, and 2016 BMW 535i xDrive. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING: Danger of injury!
Refrigerant circuit is under high pressure!
Observe SAFETY INFORMATION  for handling refrigerant and refrigerant oil.
IMPORTANT: Risk of damage!
Restart engine only when air conditioning system has been correctly filled.
Follow notes for OPENING AND REPLACING PARTS in refrigerant circuit.
If air conditioning system is opened for more than 24 hours: Replace DESICCANT INSERT FOR A/C SYSTEM 

Necessary preliminary work: 

Unclip fan cowl (1) at clamps (2) on left and right, feed out in upward direction and loosen from cooler package cover.

Fig 1: Removing Fan Cowl
G06889285Courtesy of BMW OF NORTH AMERICA, INC.

Release screws (1) on left and right from cover (3).

Tightening torque 17 10 1AZ .

Release screws (2) behind sealing lip.

Tightening torque 17 10 1AZ .

Lift out cover (3).

Fig 2: Identifying Screws And Cover
G06889272Courtesy of BMW OF NORTH AMERICA, INC.

Release screws (1).

Tightening torque 64 53 3AZ .

Remove heating and air conditioning lines (2) in direction of arrow and place to one side.

Installation note: 

Replace sealing rings.

Use special tool 00 9 030 to install sealing rings without damaging them.

Lift out capacitor (3).

Fig 3: Lifting Out Capacitor
G05479023Courtesy of BMW OF NORTH AMERICA, INC.

After installation: