64 53 521 Replacing safety pressure switch (N63)
Refrigerant circuit is under high pressure!
Avoid contact with refrigerant and refrigerant fluid.
Read and comply with safety information:
- Observe SAFETY INFORMATION for handling refrigerant and refrigerant oil.
Restart engine only when air conditioning system has been correctly filled.
Follow notes for OPENING AND REPLACING PARTS in refrigerant circuit.
If air conditioning system is opened for more than 24 hours: Replace dryer insert for air conditioning. See REPLACING DESICCANT INSERT or REPLACING DESICCANT INSERT (CAPACITOR REMOVED) .
Necessary preliminary work:
- DRAIN OFF AIR CONDITIONING SYSTEM
- Disconnect BATTERY EARTH LEAD
- Remove RIGHT SUSPENSION CROSS-BRACE
- Remove right INTAKE PORT
Release screws (1).
Tightening torque 12 90 2AZ .
Remove electronics box cover (2).
Unclip and unplug all connectors (1) from control units.
Unclip grommet hold-down device (2) and remove.
Detach rubber grommets (3) from electronics box.
Place wiring harnesses to the side.
Installation note:
Make sure grommets are is correctly seated (for watertightness).
Release screw (1).
Remove lead (2) from connecting piece.
Unfasten plug connection (1) and disconnect.
Release safety pressure switch (2).
Tightening torque 64 53 8AZ .
After installation: