64 51 001 Cleaning evaporator
Special tools required:
Wear protective rubber gloves and protective goggles.
If cleaning agent comes into contact with eyes or skin, wash immediately with lots of water.
COMPLY WITH NOTES AND INSTRUCTIONS ON HANDLING CLEANING AGENTS
- Close all air vents
- Heater - A/C system must be switched to air recirculation function
- Cover carpet in work area
Recycling:
Carry out the cleaning operation in a suitable washing bay as the emerging cleaning agent escapes through the drain openings in the transmission tunnel.
After completing cleaning, allow car to drip-dry for approx. 5 minutes.
Necessary preliminary tasks:
Step 1:
Insert special tool 2 222 502 in the rear opening of the microfilter housing (1) at position (2) as shown.
Move special tool 2 222 502 from top downwards (A) up to stop.
At the same time, press special tool 2 222 502 at position (1) in the direction of the arrow against the microfilter housing.
Spray approximately half of the cleaning agent. Then pull the special tool 2 222 502 out of the microfilter housing.
Step 2:
Insert special tool 2 222 502 in the rear opening of the microfilter housing (2) at position (1) as shown.
Move special tool 2 222 502 from top downwards (A) up to stop.
At the same time, press special tool 2 222 502 at position (1) in the direction of the arrow against the microfilter housing.
Spray the remaining half of the cleaning agent. Then pull the special tool 2 222 502 out of the microfilter housing.
Start the vehicle and let the heating and air conditioning system run for at least 5 minutes at maximum blower output.
In order to eliminate the last remnants of cleaning agent, repeat this process shortly before handover to the customer.