37 10 001 Initial operation with test run of Dynamic Drive
WARNING: This page does not describe the selected car, but rather 21 other vehicles, including the 2017 BMW 550i GT xDrive, 2017 BMW 535i GT xDrive, 2017 BMW 535i GT, 2016 BMW 550i GT xDrive, and 2016 BMW 535i GT xDrive. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
The Service function Initial operation of Dynamic Drive must be carried out after:
- Work on the Dynamic Drive system which involved opening hydraulic lines
- Replacement/Programming/Coding Dynamic Drive control unit (ICM-V-High)
IMPORTANT:
Adhere to the utmost cleanliness. Do not allow any dirt to enter the hydraulic system.
Using contaminated equipment to add fluid may introduce dirt particles into the fluid reservoir and significantly reduce the service life of the ARS and power steering system. Do not use any filler funnels or similar!
Use only Pentosin CHF11S from original containers!
The fill level may only be checked or adjusted when the engine is stopped! Adjust fill level if possible in middle between 20° and 80° C.
Using contaminated equipment to add fluid may introduce dirt particles into the fluid reservoir and significantly reduce the service life of the ARS and power steering system. Do not use any filler funnels or similar!
Use only Pentosin CHF11S from original containers!
The fill level may only be checked or adjusted when the engine is stopped! Adjust fill level if possible in middle between 20° and 80° C.
NOTE:
To avoid mix-ups when filling with hydraulic fluid, mark the fluid reservoirs or their caps with identification marks.
CHF Pentosin CHF11S
Bleeding hydraulic circuit
- Thoroughly clean fluid reservoir and its immediate surroundings with cap closed
- Check and correct fill levelNOTE: The fill level must not be above the "MAX" mark (80 °C) with the engine at normal operating temperature.
When filling observe temperature indication of dipstick.
Hydraulic fluid: refer to OPERATING FLUIDS
- Start engine
- Turn steering wheel left and right twice in each case up to full lock; if necessary, top up hydraulic fluid (e.g. if hydraulic system is completely drained)
- Move steering wheel to straight-ahead position and turn off engine
- Check and correct fill level with engine stopped
- Check reworked components on hydraulic system for leaks
Performing initial operation with test run
WARNING:
Risk of injury!
Vehicle executes heavy rolling motions during initial operation! Therefore observe the following instructions without fail:
Vehicle executes heavy rolling motions during initial operation! Therefore observe the following instructions without fail:
- Do not allow any persons to remain in the vehicle or directly on the vehicle
- Keep the vehicle doors closed.
- Maintain a safety distance around the vehicle of 1 meter to persons, objects, walls etc.
- Vehicle must be standing horizontally with all wheels on a firm surface
- Do not under any circumstances carry out initial operation on a lifting platform, wheel alignment analyzer or similar!
- Avoid heavy loads
- Check load; if necessary, remove load from the vehicle
- Bring engine up to operating temperature
- Connect vehicle to DIS or MoDiC
- Start initial operation in SERVICE FUNCTIONS. Follow instructions in Diagnosis and Information System.
- Check fill level again with engine stationary and if necessary top up oil to 80° mark.