LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 705 (General Electrical System - Repair) >> Battery >> 61 20 503 Vehicle battery - closed-circuit current monitoring

61 20 503 Vehicle battery - closed-circuit current monitoring

WARNING: This page does not describe the selected car, but rather 21 other vehicles, including the 2017 BMW 550i GT xDrive, 2017 BMW 535i GT xDrive, 2017 BMW 535i GT, 2016 BMW 550i GT xDrive, and 2016 BMW 535i GT xDrive. However, it is still accessible from the selected car via links, so may be relevant.

Necessary preliminary tasks: 

To access the ground cable of the battery, perform the Necessary preliminary work: described in DISCONNECTING BATTERY EARTH LEAD .

Do not disconnect negative lead of battery. 

Connect diagnosis system.

Connect clip-on probe to negative lead of battery. The arrow on the current clamp must point towards the battery.

Measure closed-circuit current.