65 20 030 Removing and installing/replacing empty housing for roof-mounted aerial
Special tools required:
Special tool has sharp edges!
Adapt working height to vehicle height with non-tilting and non-slip platform.
Handle special tool correctly and make sure it is positioned without tilting or slipping on the vehicle.
Risk of damage!
In order to prevent dents in the roof, do not exert any pressure on the roof.
In order to guarantee a permanent connection and adhesive hardening:
After bonding the empty housing for the roof-mounted aerial, wait 24 hours before driving the vehicle through a car wash.
Mask roof (2) around empty housing for roof-mounted aerial (3) with yellow plastic adhesive tape (1). To do so, slide plastic adhesive tape under empty housing (3) slightly.
Make sure your arms do not cross over (1) when holding special tool 65 2 010 .
Pull handle must always be ahead of the guiding hand (2).
To avoid paintwork damage on the roof and empty housing (3), do not fit special tool 65 2 010 askew.
Cut through adhesive bead all round with special tool 65 2 010 .
Pull on handle (1) and align blade on handle (2).
Remove empty housing (3).
Installation
Empty housing for roof-mounted aerial is secured with window glass adhesive. All preparatory operations correspond to the WINDOW BONDING NOTES .
Bonding surface (2) must be clean and free from grease.
Apply trace of adhesive bead all round outer contour as follows.
Distance between adhesive bead and edge of aerial cover:
A. 6.5 mm ±1 mm
Start and end of bead trace must have an overlap length of max. 10 mm.
Secure empty housing if necessary with adhesive tape and press down uniformly.
After bonding, leave vehicle to stand for at least 3 hours at room temperature.