LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 352 (Heating And Air Conditioning - Repair) >> Air Conditioning System >> 64 50... Leak detection with ultraviolet additives (UV additives) (BMW leak-testing case)

64 50... Leak detection with ultraviolet additives (UV additives) (BMW leak-testing case)

WARNING: This page is about a different car, the 2013 BMW 550i GT, 2012 BMW 550i GT, 2011 BMW 550i GT, and 2010 BMW 550i GT. However, it is still accessible from the selected car via links, so may be relevant.
IMPORTANT: In EU countries, only limited UV leak detection is permitted!

Observe national regulations in all other countries!

IMPORTANT: It is absolutely essential to read and comply with the equipment manufacturer's operating instructions use provided in the equipment case!

Read and comply with the manufacturer's operating instructions provided with the special tool particularly with regard to accident prevention, health protection and environmental protection.

Use only BMW-approved UV additives (e.g. TRACER). 

Only the basic procedure is described in the following! 

IMPORTANT: UV additives may not be used in vehicles with electric A/C compressors!
WARNING: Avoid contact with refrigerant.

Follow safety precautions when handling refrigerant.  See 64 50... INSTRUCTIONS FOR HANDLING R 134A REFRIGERANT , 64 50... SAFETY INFORMATIONS FOR HANDLING TETRAFLUORETHANE REFRIGERANT R134A  or 64 50... SAFETY INFORMATIONS FOR HANDLING REFRIGERANT OIL .

IMPORTANT: Ultraviolet lamp gets very hot in the radiation area!

Do not use the ultraviolet lamp without the filter glass.

Eyes and skin will suffer damage if the ultraviolet lamp is used without the filter glass.

When using the ultraviolet lamp, wear the safety goggles provided in the case.

NOTE:
  • Fill the hose system of the hand pump completely with UV additive PRIOR to use
  • The UV additive may be used exclusively for BMW-approved refrigerant oils
  • Do not operate the air conditioning system while the hand pump is connected or in use
  • The air conditioning system must always be filled with an adequate amount of refrigerant to enable the leak-detecting agent to be properly distributed

Necessary preliminary tasks 

Before actually testing for leaks, check the entire refrigerant circuit using the UV leak detection lamp to ensure that no UV additive is already in the area of the refrigerant circuit.

Leak areas which have already been detected by UV light must carefully cleaned with the cleaning agent provided in the case.

On initial use: 

Connect hand pump (1) to additive cartridge (2) and hose piece (3).

Fig 1: Identifying Hand Pump, Additive Cartridge And Hose Piece
G04747933Courtesy of BMW OF NORTH AMERICA, INC.

On initial use: 

Attach vent valve (1) to quick-release coupling (2).

Turn handle (3) on hand pump to advance the piston until a small amount of UV additive emerges. This vents the hose system.

IMPORTANT: The entire hand pump with hose system must not be disassembled again once the filling work has been completed.
Fig 2: Attaching Vent Valve To Quick-Release Coupling
G04747934Courtesy of BMW OF NORTH AMERICA, INC.

Attach quick-release coupling (1) to low-pressure connection (2) of air conditioning system.

Turn handle on hand pump (3) until the required amount of UV additive is added.

The quantity of UV additive to be added is dependent on the AMOUNT OF REFRIGERANT IN THE REFRIGERANT CIRCUIT:

NOTE: After filling, remove quick-release coupling (1) and if necessary use the cleaning agent contained in the special tool case to clean up the UV additive.

Further tasks: 

Complete accompanying information label (1) with the relevant data and attach in an easily visible position next to the filling capacity information label (2).

Fig 4: Identifying Accompanying Information Label And Filling Capacity Information Label
G04747936Courtesy of BMW OF NORTH AMERICA, INC.