LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2014 >> M6 2D Convertible, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 352 (Heating And Air Conditioning - Repair) >> Air Conditioning System >> 64 50 010 Drawing off, evacuating and filling heating and air conditioning system (R134a)

64 50 010 Drawing off, evacuating and filling heating and air conditioning system (R134a)

WARNING: This page is about a different car, the 2013 BMW 550i GT, 2012 BMW 550i GT, 2011 BMW 550i GT, and 2010 BMW 550i GT. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Only persons in possession of a professional certificate of competence for the maintenance and repair of heating and air conditioning systems  are authorised to carry out repair work on the refrigerant circuit. It must be available no later than 04 July 2010 (applies only to EU countries; follow country-specific regulations in non-EU countries).

Refrigerant circuit is under high pressure!

Repair work may only be carried out on a depressurised  refrigerant circuit!

Avoid contact with refrigerant and refrigerant oil.

IMPORTANT: Risk of damage!
Only BMW-approved R134a refrigerant may be used.

Restart engine only when the air conditioning system has been correctly filled.

Vehicle-specific notes 

F02/F03/F04 only: 

To ensure a virtually complete draining of refrigerant from the automatic rear air-conditioning system or the hybrid battery cooling system:

In the diagnosis system under Service functions carry out the instructions for "Draining/filling refrigerant circuit".

Only M5 (S63): 

To access refrigerant line connections, the right intake silencer housing must be removed.

F01/F02/F03/F04/F06/F12/F13 (N63) only from 07/2012: 

To access refrigerant line connections, the right intake port must be removed.

IMPORTANT: Risk of damage!

Carefully move the climate service station!

Comply with the operating instructions and service interval for the A/C service station!

Make sure that the hoses of the A/C service station are drained after the drawing off or filling procedure!

The climate service station contains highly sensitive components, such as scales.

These components will be damaged due to improper handling, such as fast driving over a bump. This will result in a significant reduction of the measuring accuracy when drawing off and filling.

IMPORTANT: The vehicle must be parked on the ground during all draw-off, evacuation and filling procedures!

Filling a raised vehicle will result in insufficient filling levels.

Fig 1: Drawing Off Air Conditioning System Refrigerant Oil
G04747948Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: In case of complaints, carry out a heating and air conditioning performance test!

If the system fails the test, draw off, evacuate and fill the heating and air conditioning system in accordance with the operating instructions of the relevant service station.

Instructions for drawing off heating and air conditioning system: 

To help separation of refrigerant and refrigerant oil, run engine at low speed (800-1200 rpm) and with heating and air conditioning system turned on for a few minutes.

The limits the entrainment of refrigerant oil while it is drawn off.

Drawn-off refrigerant oil must be changed and reintroduced via the A/C service station.

During drawing off, set blower of heating and air-conditioning unit to middle blower speed. This ensures that drawing off is more effective since the pressure on the low pressure side increases.

Recycling:

Dispose of drawn-off refrigerant oil as hazardous waste.

Observe country-specific waste disposal regulations.

Instructions for evacuating heating and air conditioning system: 

Before each filling, evacuate the refrigerant system.

Observe an evacuation time of at least 30 minutes  .

The evacuation procedure removes all traces of ambient air, water vapour and any other gases present from the heating and air conditioning system. This enables subsequent system filling with refrigerant.

If the vacuum does not remain stable when the system is off, run the procedure for leaks in the refrigerant circuit.

During evacuation, set blower of heating and air-conditioning unit to middle blower speed. This ensures that evacuation is more effective since the pressure on the low pressure side increases.

Instructions for filling heating and air conditioning system: 

Before filling with refrigerant, replace the refrigerant oil entrained during drawing off.

Also top up any lost fluid as indicated in the table:

Loss of R134a refrigerant 

Table 1  indicates the permitted loss of refrigerant after a specific period of time. There is no leak. refrigerant oil may not be topped up.

Table 2  indicates the amount of refrigerant oil must be topped up with an unapproved loss of refrigerant due to a leak after a specific period of time.

Different cases: 

  1. Loss of refrigerant per Table 1 is not exceeded 
    • Top up lost R134a refrigerant
    • It is not permitted  to top up the refrigerant oil
  2. Loss of refrigerant per Table 1  is exceeded
    • Top up lost R134a refrigerant
    • refrigerant oil must be topped up additionally  per Table 2 
Table 1: 
Number of years since last filling 
0 -
1
1 -
2
2 -
3
3 - 4 4 - 5
Permissible loss [g] → no need to top up refrigerant oil  ≤ 30 ≤ 60 ≤ 90 ≤ 120 ≤ 150
Table 2: Number of years since last filling  R134a loss of coolant [g]  Top up quantity refrigerant oil 
0 - 1 - <120 0
120 - 150 10
>150 20
1 - 2 - <180 0
180 - 210 10
>210 20
2 - 3 - <240 0
240 - 270 10
>270 20
3 - 4 - <300 0
300 - 330 10
>330 20
4 - 5 - <360 10
>360 20

Follow NOTES FOR OPENING AND REPLACING PARTS  in refrigerant circuit.

Depending on the type of component replaced on the heating and air conditioning system, it may be necessary to the top up the refrigerant oil, even if no measurable losses have occurred during drawing off. Follow the notes provided by the heating and air conditioning system manufacturer, taking account of the tolerances (and inaccuracies) indicated in the operating instructions of the relevant service station.

Fig 2: Identifying Heating And Air Conditioning System Type Plate
G04747937Courtesy of BMW OF NORTH AMERICA, INC.

Information on the required refrigerant fill quantity for the entire heating and air conditioning system is contained on the type plate (1) in the engine compartment.

If necessary, refer to the Technical Data for CAPACITY .

Installation note 

Reseal refrigerant filler necks on vehicle with sealing caps.