61 21 028 Charge battery
Overview of Activities
Key processes
- Charge battery
Additional Information
General information
Key processes
- Charge battery
TECHNICAL INFORMATION
Observe the notes on handling the vehicle battery.
For more information see:
61 00... Safety instructions for handling vehicle battery
61 00... Notes for disconnecting and connecting battery
61 12... Information on intelligent battery sensor (IBS)
- Charging lead-acid batteries and AGM batteries
- Connect to a charger approved by BMW.
- If the battery is charged while it is still installed: always connect the charger to the jump start terminal point in the engine compartment.
- Fully charge the battery.
The battery is fully loaded once the charge current drops below a certain value:
Battery temperature Charge current 15° C - 25° C <2.5 A < 15°C <1.5 A - Disconnect the charger after having completed charging.
- Charge lithium ion battery
TECHNICAL INFORMATION
Comply with notes on handling lithium ion batteries.
- Adapt the charging voltage on the charger to the lithium ion batteries.
Too high charging voltage can lead to opening of the electronic disconnect switch.
- Connect to a charger approved by BMW.
- Fully charge the battery.
- Disconnect the charger after having completed charging.
- Adapt the charging voltage on the charger to the lithium ion batteries.