Action in service
After this fault, an active test is automatically activated (secondary fault in fault memory!).
- Read out result of active test (Are there other faults in the fault memory? => Then continue there!)
- Run system test Swapped exhaust gas oxygen sensors Follow instruction for system test.
- If system test shows no result, then
- Visual inspection of wiring and connectors
- Test the wiring
- Replace lines or connectors if necessary
- Check exhaust system for tightness before post-catalyst sensor
- Replace downstream catalytic converter of exhaust gas sensor
- Replace primary catalytic converter of exhaust gas sensor
- Replace control unit