67 62 000 Removing and installing or replacing flat motor for front left or right power window unit

Necessary preliminary tasks: 

NOTE: Position power window unit so that screws of flat motor are freely accessible

Release screws (1) and detach flat motor (2) from power window unit.

Installation: 

Retaining pins (3) must not be released!

Fig 1: Identifying Power Window Unit Motor, Retaining Pin And Screw
G06214006Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.

Tighten first screw (1), then screw (2) and finally screw (3).

Tightening torque 67 62 1AZ

Fig 2: Identifying Power Window Unit Flat Motor Mounting Screws
G06214007Courtesy of BMW OF NORTH AMERICA, INC.

After installation: 

An initialization must be carried out in order to activate anti-trapping protection.