13 31 028 Checking fuel delivery pressure (N57 D30 U/O/T/S 0/1)
Special tools required:
NOTE:
- Connect BMW diagnosis system
Recycling:
Catch and dispose of escaping fuel in a suitable container.
Observe country-specific waste disposal regulations.
Disconnect snap fastener (1) from feed line (2).
Insert special tool 13 5 270 in the disconnected feed line.
Screw onto special tool 13 5 270 , special tool 11 4 310 .
Screw IMIB 100 bar pressure sensor (1) on the special tool 11 4 310 .
NOTE:
As an alternative to the 100 bar IMIB pressure sensor (1), the 25 bar pressure sensor can also be used. For this, screw on special tool 11 5 364 instead of special tool 11 4 310
into special tool 13 5 270
. Or directly screw the pressure manometer from the set of special tools 13 3 060
onto the special tool 13 5 270
.
Establish fuel delivery pressure. Read off fuel delivery pressure on IMIB and compare with values in diagnosis system.