12 14 523 Replacing pulse sensor on intake camshaft (N20, N26)
IMPORTANT:
Read and comply with notes on PROTECTION AGAINST ELECTROSTATIC DISCHARGE (ESD PROTECTION)
.
Necessary preliminary tasks:
- Read out the fault memory of the DME control unit.
- Switch off ignition.
- Remove INTAKE SILENCER HOUSING .
Unlock connector (1) and remove.
Release screw.
Tightening torque 13 62 1AZ .
Remove pulse sensor (2).
Check gasket, renew damaged gasket.
NOTE:
Check stored fault message.
Delete fault memory.
Delete fault memory.