Action in service
Following applies to all other versions:
Check wires and plug connections between the following components:
- DME.
- Cutoff relay, electric fan.
Check cutoff relay:
- Ignition off (no after-run of the electric fan): at both screw connections 0 V.
- Ignition on: at both screw connections approx. 12 V.
- Supply of the two plug connections with 12 V: Relay switches.
- Supply of the two plug connections with 12 V: Continuity between the two screw connections.
If necessary, renew cutoff relay.
Following applies to all other versions:
Check wires and plug connections between the following components:
- Engine control unit.
- Electric fan.
Check cutoff relay:
- Ignition off (no after-run of the electric fan): at both screw connections 0 V.
- Ignition on: at both screw connections approx. 12 V.
- Supply of the two plug connections with 12 V: Relay switches.
- Supply of the two plug connections with 12 V: Continuity between the two screw connections.
If necessary, renew cutoff relay.