Fault description
Diagnosis monitors the high pressure fuel system for pressure deviations.
Fault monitoring conditions:
The fault is detected if the fuel pressure drops below a value depending on the characteristic map in the high-pressure fuel system and/or low-pressure fuel system and the oxygen sensor control factor and/or the air/fuel ratio exceed the upper threshold value (rich mixture limit).