LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> Z4 28i, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 971 (General Electrical System - Repair - F13) >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Notes for opening contacts and locks of different plug contact systems >> 61 13... Socket housing (radio connector), Hybrid System MQS/MPQ

61 13... Socket housing (radio connector), Hybrid System MQS/MPQ

WARNING: This page does not describe the selected car, but rather 27 other vehicles, including the 2017 BMW M6, 2017 BMW 650i xDrive, 2017 BMW 650i, 2017 BMW 640i xDrive, and 2017 BMW 640i. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the connector housings:

Removing MPQ contacts from radio connector: 

Press lock (1) in direction of arrow.

Detach secondary lock (2) from radio plug.

Fig 1: Detaching Secondary Lock From Radio Plug
G10063843Courtesy of BMW OF NORTH AMERICA, INC.

Feed special tool 61 0 314 (61 1 135) past side of contact.

Press special tool 61 0 314 (61 1 135) in direction of arrow.

Pull wire (1) with socket contact out of radio connector (2).

Fig 2: Pulling Wire/Socket Contact Out Of Radio Connector
G10063844Courtesy of BMW OF NORTH AMERICA, INC.

Removing MQS contacts from contact carrier: 

Press lock (1) in direction of arrow and pull housing (2) out of radio connector.

Fig 3: Pulling Housing Out Of Radio Connector
G10063845Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1) in direction of arrow. Pull contact carrier (2) out of housing (3).

NOTE: When the contact carrier is pulled out, the secondary locks of the socket contacts are raised.
Fig 4: Pulling Contact Carrier Out Of Housing
G10063846Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Schematic diagram shows the 8-pin socket housing by way of example.

Hold down retaining hook (1) of socket contact in opening of contact carrier with a small screwdriver.

Pull wire with socket contact in direction of arrow as far as secondary lock (2).

Fig 5: Identifying Retaining Hook And Secondary Lock
G10063847Courtesy of BMW OF NORTH AMERICA, INC.

Hold down retaining hook in secondary lock (1) again. Pull wire with socket contact (2) out of contact carrier (3).

Fig 6: Pulling Cable With Socket Contact Completely Out Of Contact Carrier
G10063848Courtesy of BMW OF NORTH AMERICA, INC.

Removing MPQ contacts from contact carrier: 

Remove contact carrier (1) with MQS contacts from radio connector.

Raise lock (2) on radio connector.

Pull contact carrier (3) out of radio connector.

Fig 7: Pulling Contact Carrier Out Of Radio Connector
G10063849Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1) in direction of arrow.

Pull secondary lock (2) in direction of arrow completely out of contact carrier (3).

Fig 8: Pulling Secondary Lock Out Of Contact Carrier
G10063850Courtesy of BMW OF NORTH AMERICA, INC.

Press special tool 61 0 314 (61 1 135) on inside of contact into contact carrier (2).

Pull wire with socket contact (1) out of contact carrier (2).

Fig 9: Pressing Special Tool (61 0 314) Into Contact Carrier
G10063851Courtesy of BMW OF NORTH AMERICA, INC.