11 65 300 Removing and installing/replacing the electrical actuator drive for the wastegate (N55)
Precondition: Coolant pump has been removed. For additional information, see REMOVING AND INSTALLING/REPLACING COOLANT PUMP (N55) .
Electrostatic discharge. Damage to or destruction of electrical components.
- Leave the electrical components in their original packaging until they are being installed. Only use the original packaging for returning the product. Always package removed components straight away.
- Read and comply with user information on using the associated special tool 12 7 060.
- Only tap the housings of electrical components. Do not tap pins or multi-pin connectors directly.
- Wear electrically conductive clothing and antistatic shoes (with ESD symbol).
- For additional information see: NOTES ON ESD (ELECTROSTATIC DISCHARGE) .
- Check function of DME
- Service functions
- Drive
- Engine electronics
- Adjustment programs
- Adjusting wastegate linkage
- Wastegate valve controller NOTE:
The adjustment nuts must be locked using 2 open-end wrenches. If only one open-end wrench is used, there is a risk of the electrical controller drive being damaged.
- Loosen lock nut (1).
Remove wastegate valve linkage (3) from the drive linkage.
Unscrew adjusting nut (2).
- Removing the wastegate valve controller
- Loosen screws (1).
- Remove the electrical controller drive (2).
- View of the wastegate valve controller
- Electrical wastegate valve controller (1)
on the exhaust turbocharger.
Adjusting nut (2)
Lock nut (3)
Wastegate valve linkage (4)
- Electrical wastegate valve controller (1)
on the exhaust turbocharger.
- Setting the wastegate valve controller to the basic setting
- Adjust the standard caliper gauge (3) to the dimension
Dimension (A) = 26.6 mm
- Adjust the control rod (1) of the electrical wastegate valve controller (2) to the dimension (A).
- Adjust the standard caliper gauge (3) to the dimension
- Screwing on the wastegate valve actuator
- Position the electrical wastegate valve controller (2) on the exhaust turbocharger.
Secure the electrical wastegate valve controller with screws (1) using special tool 0 495 018 (11 4 350) .
WASTEGATE VALVE CONTROLLER AND EXHAUST TURBOCHARGER SCREWS TIGHTENING TORQUE SPECIFICATIONM4x12 2 ± 0.3 Nm - Attaching the wastegate linkage to the wastegate valve actuator NOTE:
The adjustment nuts must be locked using 2 open-end wrenches. If only one open-end wrench is used, there is a risk of the electrical controller drive being damaged.
- Screw in the adjusting nut (1) on the electrical wastegate valve actuator until the limit position.
- Position the wastegate linkage in the direction of the arrow on the electric wastegate valve actuator.
- Close the adjusting lever by hand in the direction of the arrow.
- Position the adjustment nut (1) on the wastegate linkage.
- Tighten the lock nut (2).
Courtesy of BMW OF NORTH AMERICA, INC.
Tightening torque for lock nut on wastegate valve controller to exhaust turbocharger:
M6 6.6 ± 1 Nm