Special tools required: 

Type Engine Adapter Y from 17 0 100
E60/E61/E63/E64 All 17 0 113
E65/E66 M54/N52/N62/N62T/N73 17 0 105
E65/E66 M57S/M57T/M67/M67T 17 0 113
E70/E71/E72 All 17 0 113
E81/E82/E84/E87/E88/E89 All 17 0 113
E83 M54/N46/N52K 17 0 105
E83 M47S/M57S/M57T/M57Y/N47 17 0 113
E85/E86 All 17 0 105
E90/E91/E92/E93 All 17 0 113
R50/R52 W10 17 0 107 and 17 0 102
R50 W17 17 0 109
R52/R53 W11 17 0 109
R55/R56/R57/R58/R60/R61 All 17 0 109
F25 All 17 0 113
F20/F21/F30/F31 N47 D20 K/U/O/T 1 17 0 113
F20/F21/F30/F31/F35 N13/N20 17 0 113
F30/F31/F35 N55/N55 hybrid car 17 0 113
F30/F31 N57 D30 O/T 1 17 0 113
IMPORTANT: Lifetime coolant filling: 
Never reuse used coolant!
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be drained and refilled.
In the case of other removal work involving the draining of part quantities of coolant, replace these quantities which have been drained with new coolant.
IMPORTANT: You must protect the alternator against contamination by coolant when carrying out repair work on the cooling circuit.

Cover alternator with suitable materials.

Failure to comply with this procedure may result in an alternator malfunction.

Note on ordering:

IMPORTANT: Risk of slipping due to coolant on the floor.
Danger of injury! 

Catch and dispose of emerging coolant in drip tray (1) and if necessary special tool 00 2 030 (universal hydraulic lifting equipment).

Recycling:

Observe country-specific waste disposal regulations.

Fig 1: Identifying Drip Tray And Special Tool 00 2 030
G05476170Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Check all the coolant hoses before filling the cooling system with the vacuum filling unit.
If necessary, replace damaged and porous coolant hoses.
Fig 2: Checking Coolant Hoses Before Filling Cooling System With Vacuum Filling Unit
G06889253Courtesy of BMW OF NORTH AMERICA, INC.

Preconditions

Select adapter (Y) according to table and connect to coolant expansion tank.

Connect filler unit to adapter connection (X).

Fig 3: Connecting Filler Unit To Adapter Connection (X)
G06853591Courtesy of BMW OF NORTH AMERICA, INC.

Shutoff valves (A) and (B) of the filling unit (1) must be closed.

(X) Expansion tank connection

Fig 4: Identifying Shutoff Valves (A) And (B) Of Filling Unit Is Closed
G06853592Courtesy of BMW OF NORTH AMERICA, INC.

Connect venturi nozzle (1) to filling unit (2).

(X) Expansion tank connection

Fig 5: Connecting Venturi Nozzle To Filling Unit
G06853593Courtesy of BMW OF NORTH AMERICA, INC.

Connect compressed air (1).

(X) Expansion tank connection

Fig 6: Connecting Compressed Air
G06853594Courtesy of BMW OF NORTH AMERICA, INC.

Open shutoff valve (B).

The venturi nozzle produces a flow noise.

Fig 7: Opening Shutoff Valve (B)
G06853595Courtesy of BMW OF NORTH AMERICA, INC.

Then open shutoff valve (A) until the filling hose (1) is free of bubbles.

Close shutoff valve (A) again. The filling hose (1) is vented in this way.

Fig 8: Opening Shutoff Valve (A) Until Filling Hose Is Free Of Bubbles
G06853596Courtesy of BMW OF NORTH AMERICA, INC.

Shutoff valve (B) remains open. Generate vacuum in coolant system for approx. 2 minutes. The end vacuum is reached at a vacuum of -0.7 to -0.95 bar. Green scale on the vacuum meter.

NOTE: The coolant hoses contract during vacuum build-up.

Then close shutoff valve (B) again.

Fig 9: Identifying Shutoff Valve (B) Remains Open
G06853597Courtesy of BMW OF NORTH AMERICA, INC.

Both shutoff valves (A) and (B) must be closed. Then seal Venturi nozzle (1).

Fig 10: Identifying Shutoff Valves (A) And (B) Closed
G06853598Courtesy of BMW OF NORTH AMERICA, INC.

The cooling system must hold the vacuum for 30 s. If the needle in the vacuum meter falls, this indicates a leak in the cooling system.

If the vacuum remains constant, proceed with filling.

In event of leaks, check cooling system for leaks.

Fig 11: Checking Cooling System For Leaks
G06853599Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: There must be sufficiently premixed coolant in the filling unit container: 1 - 2 litres more than the vehicle filling capacity.
Position the filling unit container at the same height as the coolant expansion tank.

Shut-off valve (B) remains closed during the filling process.

To fill the cooling system, open shutoff valve (A) to filling unit container.

Fig 12: Opening Shutoff Valve (A)
G06853600Courtesy of BMW OF NORTH AMERICA, INC.

Coolant is now added.

The filling procedure is finished when the needle in the vacuum meter is at 0 bar or no longer falls.

If necessary, reduce remaining vacuum. Open shutoff valve (B) to do so.

Fig 13: Opening Shutoff Valve (B)
G06889264Courtesy of BMW OF NORTH AMERICA, INC.

Remove filling unit with adapter from expansion tank.

Adjust coolant level to maximum.

Close coolant expansion tank.

Fig 14: Closing Coolant Expansion Tank
G06853602Courtesy of BMW OF NORTH AMERICA, INC.

After the cooling system has been filled with the vacuum filling unit, another bleeding procedure must be performed for the following vehicles:

After the cooling system has been filled with the vacuum filling unit, another bleeding procedure must be performed for vehicles with an electric coolant pump:

NOTE: Do not open the coolant expansion tank cap during the bleeding procedure.
Switch on the low-beam headlights to perform the bleeding procedure. If the low-beam headlights are not switched on, the ignition (Terminal 15) will switch off automatically after a certain period of time and interrupt the bleeding procedure.
  1. Connect battery charger.
  2. Switch the ignition on.
  3. Switch on low-beam headlight.
  4. Set heating to maximum temperature. Take back blower to smallest stage.
  5. FES (driving experience switch) must not be in ECO PRO!
  6. Press accelerator pedal for 10 seconds to floor. Engine  must not  be started.
  7. The venting procedure is started when the accelerator pedal is pressed and takes approx. 12 minutes. (Electric coolant pump was activated and shuts down automatically after approx. 12 min).
  8. Then adjust fluid level in the coolant expansion tank to maximum.
  9. Check cooling system for leaks.
  10. If the ventilation has to be performed again, deactivate DME completely (remove ignition key for approx. 3 minutes). Then repeat from point  3.

Check function of cooling system.

Check cooling system for tightness.