11 65 714 Removing and installing/renewing electric changeover valve on exhaust turbocharger, right (S63)
Necessary preliminary tasks:
- Remove acoustic cover.
- Remove INTAKE FILTER HOUSING .
electric changeover valve, cylinder 1-4
Disconnect plug connections (1) on pressure converter.
Installation:
Plug connections (1) must snap audibly into place!
Unfasten screws (2).
Tightening torque 11 65 8AZ .
Remove pressure converter.
Assemble engine.
Follow diagnosis instruction.
- Complete vehicle
- Drive
- Engine electrical system
- Air supply
- Boost pressure control