LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> X5 M >> Repair and Diagnosis >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> Distance Systems, Cruise Control - Repair >> Reversing Camera >> 66 53 010 Calibrating reversing camera (from 10/2009)

66 53 010 Calibrating reversing camera (from 10/2009)

NOTE: Calibration of reversing camera must be carried out after the following work:
  • Removal and installation/replacement of reversing camera
  • Body repair work at rear end of vehicle
  • Adjusting work at tailgate
IMPORTANT: Follow instructions and specifications in procedure. 
To obtain an optimum result, always adhere to the following conditions:
  • Vehicle standing level on headlight aiming station
  • Correct tire inflation pressure (see label on vehicle).
  • Vehicle is free of load
  • Rear seat bench is unoccupied
  • Do not swap seats during calibration
  • Steering wheel in straight-ahead position
  • Do not move steering wheel
NOTE: Also switch on reversing camera by means of PDC button.

Calibration can only be carried out with the BMW diagnosis system.

Use of a special tool is no longer required from 10/2009!

Service functions: