Repair procedures (plant/service)
intermittent open circuits
-IBS disconnected, Terminal 15 off, wake-up wire shorted to positive: Check wake-up wire and other components connected to the wake-up wire
-IBS disconnected, Terminal 15 off, wake-up wire shorted to ground: Check wake-up wire
-IBS connected, Terminal 15 off, wake-up wire shorted to positive: Replace IBS IBS connected, Terminal 15 on, wake-up wire shorted to ground: