Condition for fault identification
Voltage condition:
None
Temperature condition:
The ambient temperature at engine start must be higher than -7.5°C
$(C TAM MIN TIA PLAUS DIAG) and lower than 35.3°C
$(C_TAM_MAX_TIA_PLAUS_DIAG).
Time condition:
None
Other conditions:
speed >40 km/h $(C VS MIN TIA PLAUS DIAG) for >120 s $(C_T_VS_MIN_TIA_PLAUS_DIAG)