64 52... Instructions for opening and part replacement in refrigerant circuit
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2016 BMW 328i xDrive, 2016 BMW 328d xDrive, 2015 BMW 328i xDrive, 2015 BMW 328d xDrive, and 2014 BMW 328i xDrive. However, it is still accessible from the selected car via links, so may be relevant.
Special tools required:
WARNING:
- Avoid contact with refrigerant and refrigerant oil
- Follow safety informations for HANDLING REFRIGERANT
- Follow safety information for HANDLING REFRIGERANT OIL
Attention!
- Always use new O-rings each time A/C connections are opened
They must not be coated.
Use special tool 00 9 030 to install sealing rings without damaging them.
- Open the refrigerant circuit for as short of a period as possible.
- Close all components and lines in the refrigerant circuit and return parts immediately following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
- If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 h, the dryer insert for the air conditioning must be replaced.
- Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage.
(minor leak, e.g. hairline crack)
Procedure:
- Draw off HEATING AND AIR CONDITIONING SYSTEM , then determine drawn-off amount of refrigerant oil
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 10 ml
- Capacitor: 20 ml
- Desiccant insert/dryer flask: 20 ml
- Each replaced refrigerant line: 10 ml
- Condenser with integrated dryer flask: 40 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- Only I01: Radiator, high-voltage battery unit: 20 ml
- EVACUATE AND FILL AIR CONDITIONING SYSTEM
- Part replacement due to sudden leakage
(major leak, e.g. pipe break due to accident)
Procedure:
- Draw off HEATING AND AIR CONDITIONING SYSTEM , then determine drawn-off amount of refrigerant oil
- Carry out part replacement
- Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
- Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
- Evaporator: 35 ml
- Capacitor: 35 ml
- Desiccant insert/dryer flask: 55 ml
- Each replaced refrigerant line: 35 ml
- Condenser with integrated dryer flask: 55 ml
- Safety pressure switch and gasket: no additional refrigerant oil
- Only I01: Radiator, high-voltage battery unit: 35 ml
- EVACUATE AND FILL A/C SYSTEM