LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> 740Lxi >> Repair and Diagnosis >> External Pages >> Different car >> Section 960 (Maintenance And General Information - Repair -- F31) >> HVAC >> 64 52... Instructions for opening and part replacement in refrigerant circuit

64 52... Instructions for opening and part replacement in refrigerant circuit

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2016 BMW 328i xDrive, 2016 BMW 328d xDrive, 2015 BMW 328i xDrive, 2015 BMW 328d xDrive, and 2014 BMW 328i xDrive. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

WARNING:

Attention! 

  1. Part replacement as preliminary work fur further repair work and part replacement based on gradual leakage. 

    (minor leak, e.g. hairline crack)

    Procedure: 

    • Draw off HEATING AND AIR CONDITIONING SYSTEM , then determine drawn-off amount of refrigerant oil
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
      • Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
      • Evaporator: 10 ml
      • Capacitor: 20 ml
      • Desiccant insert/dryer flask: 20 ml
      • Each replaced refrigerant line: 10 ml
      • Condenser with integrated dryer flask: 40 ml
      • Safety pressure switch and gasket: no additional refrigerant oil
      • Only I01: Radiator, high-voltage battery unit: 20 ml
    • EVACUATE AND FILL AIR CONDITIONING SYSTEM
  2. Part replacement due to sudden leakage 

    (major leak, e.g. pipe break due to accident)

    Procedure: 

    • Draw off HEATING AND AIR CONDITIONING SYSTEM , then determine drawn-off amount of refrigerant oil
    • Carry out part replacement
    • Replace removed refrigerant oil and additionally top up with new refrigerant oil according to components replaced:
      • Compressor: refer to NOTES ON COMPRESSOR REPLACEMENT
      • Evaporator: 35 ml
      • Capacitor: 35 ml
      • Desiccant insert/dryer flask: 55 ml
      • Each replaced refrigerant line: 35 ml
      • Condenser with integrated dryer flask: 55 ml
      • Safety pressure switch and gasket: no additional refrigerant oil
      • Only I01: Radiator, high-voltage battery unit: 35 ml