LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> 740Lxi >> Repair and Diagnosis >> External Pages >> Different car >> Section 479 (Collision - Body Panel Repair (F01, F02)) >> Body Repair General Information >> 41 00... Notes On Adhesive K1 >> Preparing the glue cartridge

Preparing the glue cartridge

WARNING: This page is about a different car, the 2011 BMW 750xi, 2011 BMW 750Lxi, 2010 BMW 750xi, and 2010 BMW 750Lxi. However, it is still accessible from the selected car via links, so may be relevant.

Opened glue cartridges may be used again before the expiry date as long as a new mixing tube is used.

The working temperature of glue cartridge must be at least 20°C.

Insert glue cartridge into cartridge gun, remove cap and allow both adhesive components to emerge. Strip adhesive components uniformly and attach mixing tube. Only use mixing tubes supplied with glue cartridge.

Allow approx. 10 cm of mixed adhesive to emerge and then apply the mixed adhesive first on one side of the bonding surface.

Potlife of mixed adhesive approx. 2 hours. A change of mixer is only necessary if over a period of 1 hour no material has flowed through the mixer.