64 11 865 Replacing actuator drive for recirculated air flap
WARNING: This page is about a different car, the 2011 BMW 750xi, 2011 BMW 750Lxi, 2010 BMW 750xi, and 2010 BMW 750Lxi. However, it is still accessible from the selected car via links, so may be relevant.
Necessary preliminary tasks:
Unlock plug connection (1) on automatic air recirculation control sensor (2) and disconnect.
Release screws (1) on blower housing cover (2).
Lift out blower housing cover.
Release screws (1).
Unclip relay lever (2) with a suitable tool.
Remove actuator drive (3).
Unlock plug connection (4) and disconnect.
Replacement:
Servomotors must be readdressed in the event of replacement!
Addressing can only be carried out with the BMW diagnosis system.
Service functions:
- Body
- Heating and air conditioning function
- Flap motors
- Readdress flap motors