Replace Teflon ring
Before replacing the Teflon ring (1), make sure your hands and the work surface are clean and free of oil.
Avoid mechanical contact with injector tip (2).
Remove Teflon ring (1) with special tool 13 0 191 from injector (2).
Use a fluff-free cloth only to remove combustion residues from cylindrical part of injector tip (do not use ultrasound or other tools/agents).
Do not clean injector tip.
Push new Teflon ring (1) onto the installation cone 13 0 195 .
Push Teflon ring (1) with fingers assisted by the installation cone 13 0 195 onto the injector (2).
- Do not use fingernails to slide Teflon ring on.
- Do not use any lubricating agents.
- The sealing ring is expanded when slid on.
To bring the expanded Teflon ring to its installation dimension, slide three assembly sleeves with decreasing diameters onto the injector.
Slide assembly sleeve (1) with large opening first onto injector (1).
Do not use any lubricating agents.
First slide assembly sleeve 13 0 192 (large diameter) onto injector (1).
Then slide assembly sleeve 13 0 193 (medium diameter) onto injector (1).
Finally, press injector (1) into assembly sleeve 13 0 194 (small diameter).
Installation note:
Install injector within 10 minutes or slide on protective cap (Fig. 13 14 05) Teflon ring swells up.